güvenliği için her şeyi yapın,Güvenli bir dünya için!

Metro içinde IG541 Gazaltı Yangın Söndürme Sistemi uygula

» Bizim blog Metro içinde »IG541 Gazaltı Yangın Söndürme Sistemi uygula

Metro içinde IG541 Gazaltı Yangın Söndürme Sistemi uygula

Haziran 8, 2018

özet

Underground rail transit is a new mode of transportation that alleviates road traffic pressure.

yangın güvenliği çalışmasında, the administrative and supervisory authorities have clear regulations on the installation of fire extinguishing systems and other fire extinguishing equipment.

yangın söndürme sisteminin seçimi için, considering the particularity of underground rail transit, and considering environmental protection, emniyet, economy, and fire extinguishing efficiency, we suggest using the HFC-227ea fire extinguishing system or the IG541 Inert Gas Yangın söndürme sistemi. There is no harm to humans.

çin tren istasyonu IG541 yangın söndürme sistemi

önsöz

Urban Underground railways are an important factor program of urban construction, o Kentsel ulaşım inşaatın ana arterler olduğu.

The municipal government invests heavily in underground railway construction, and the railway is normally built in the crowded strip of the city, Trafik baskıyı hafifletmek için, as crowded with people, so there is a certain risk of safety after the railway is built.

The railway/metro operates underground, so if the railway gets into an accident and causes a fire, then it will seriously harm our people.

To avoid fire in the underground railways, according to the provisions of <Metro Tasarım Kod>, in the railway system, jeneratör odası, makine dairesi, bilgisayar odası, and the power distribution equipment area are prone to catching fire.

As the railway is a particular place-underground place when we measure fire suppression, we can not be able to use a water-based fire extinguishing device because water-based is hard to reach, we should use a smart gas fire suppression system, biz onun erken aşamada yangın bulabilirsiniz sağlamak ve zaman içinde yangını söndürmek için, ve minimum kayıp.

metro IG541 yangın söndürme sistemi

1. Railway or Metro Station General Situation

1.1 Subway or Metro Project Overview

Take Metro 1 Bir örnek olarak Pekin, the construction of Metro 1 is normally designed to cross the main road, the setting railway station is normally at the location of the main road or supermarket, which continues to serve people’s travel and shopping. Örneğin, the railway station and the local supermarket shopping mall so the metro is very important in the subway construction. the subway plays an important role in underground transportation in urban areas, and it is convenient for people’s travel every day and night.

Fire Safety in the subway is serious and important.

1.2 Tasarım kapsamı

Subway fires not only cause huge damage to railway train equipment but are also harmful to human health. If one day the railway is shut down due to a fire, all train stations will be paralyzed.

2. Metro Yangın Bastırma Tasarım Prensipleri

Subway fire protection design should use an automatic fire suppression system and its device, the system should have automatic, manual control, and mechanical emergency start. Aynı zamanda, for the design of the manual control system, we should consider awareness and measurement for the manual; the subway should have a different fire supervisor, and every fire zone should use a separate toplam sel yangın söndürme sistemi.

3. Yangın Söndürme Medya Seçimi (ajan)

As the subway is driven by electric power when a fire occurs the water is not able to be used for fire suppression, only a gas fire suppression system is most suitable for the subway fire solutions, but as the subway is underground and crowded with people, böylece yangın söndürücü madde / maddenin seçimi için biz hızlı hızlı kullanmalıdır, etkili, insan güvenli gaz yangın söndürme maddesi.

3.1 Gaz otomatik yangın söndürme sistemi

There is a definite requirement and provision for a gas automatic fire suppression system when fire extinguishing, which should ensure the subway’s operation is not affected, ensure the subway equipment will not be damaged, and extinguish the fire at its early stage. an environmentally friendly fire extinguishing agent is an ideal extinguishing medium for it, to extinguish the subway fire without air pollution and any harm to the human body.

3.2 Choose IG41 fire extinguishing agent as the extinguishing media in the subway

Considering the atmosphere, the people of the earth no longer use 1301 fire extinguishing agent because it causes pollution of the atmosphere.

Carbon dioxide extinguishing agents put out fires quickly, but due to the narrowness of underground stations and train cars, carbon dioxide can be harmful.

Considering the environment, yangın söndürme verimliliği, and Human Safety factors, we choose to use the FM200 gas fire suppression system or the IG541 Fire Extinguishing System.

Considering from Environmental Protection Aspect, the indices of ODP, GWP, and ALT are 3 important factors for environmental protection. the FM200 system and the Inert Gas Fire Suppression system are both perfect.

IG41 Characteristics

For travel safety reasons, IG541 is an inert gas, consisting of nitrogen, argon, and carbon dioxide. Their proportion is 52 VS 40 VS 8. These 3 gases normally occur in the atmosphere, bu nedenle, IG541 in the composition is a natural gas.

The IG541 has the following characteristics:

  1. OPD = 0.
  2. GWP = 0.
  3. ALT = 0.
  4. Belongs to inert gases and is non-corrosive to electric equipment and facilities.
  5. Bu şeffaftır, renksiz, kokusuz.
  6. İletken olmayan.
  7. Not have secondary pollution to the atmosphere and not have bad effects on humans.

So the IG541 is very suitable to use in the subway or metro as the main fire extinguishing system.

Considering from Usage Cost Aspect, the FM200 and IG541 Inert Gas fire suppression systems are the ideal fire extinguishing systems for the current subway system.

The cost system consists of product purchase cost, maintenance cost, and transportation cost. For the FM200 system, the product purchase cost is slightly higher, while for the IG541 system, the maintenance cost and transportation costs are slightly higher.

ikisinin karşılaştırılması Yani, the cost to them is more or less the same.

4. Sonuç

After various considerations and implementation results, the IG541 gas fire suppression system is finally the most ideal fire protection system for the subway we chose.

Considering many factors such as economy, çevresel koruma, emniyet, and efficiency, before establishing a better fire extinguishing system, the IG541 fire extinguishing system should be the most reasonable fire extinguishing system applied in railways or subways.

Renksiz, kokusuz, ve aşındırıcı olmayan are the most advantageous of subway fire project installation, mühendislik, and maintenance.

IG541 gaseous fire extinguishing agent becomes the first choice for the subway.

halon alternatif gaz yangın koruma sistemi

Belki de ister