Do all for safety,for a safe world!

Fixed Fire Extinguishing Systems Electric Aerosol

» Products » Minisol Aerosol Fire Extinguisher » Fixed Fire Extinguishing Systems Electric Aerosol
  • Fixed Fire Extinguishing Systems Electric Aerosol

    CATEGORY AND TAGS:
    Minisol Aerosol Fire Extinguisher, Products

    Our aerosol-fixed fire extinguishing system produces a super-fine aerosol compound, which is a clean agent without damage to electrical equipment.

    Aerosol systems can be installed in telecommunication rooms where high-value equipment is over there.

    enquiry
    • Specifications
    • Features
    • Application
    • More Information

    The electric style of aerosol fixed fire extinguishing systems are ideal products for protecting the telecommunication room, Before we formally introduce fire extinguishers, let’s understand what is a telecommunication room.

    In a telecommunication room, there are many electrical equipment over there: power supplies, signal transceivers, SDH transmission equipment, base station equipment, power distribution box, Environment monitor, Optical distribution frame, Digital distribution frame, Wireless devices, Access devices, and Switching equipment.

    The telecommunication room also named carrier hotel, is where many electric and electrical equipment works, so it is a very important place, According to the code for fire protection design, there should be set with automatic fire suppression systems, fixed aerosol fire extinguishing systems with 1500 compounds are recommended.

    Basic Technical Parameters of Aerosol Fixed Fire Extinguishing Systems

    The following are the basic parameters:

    • Name: Fixed Aerosol fire extinguisher.
    • Product Model: AW-QH-1500E
    • Capacity: 1500 aerosol covering up to 15 cubic meters.
    • Activation Mode: electric, electronic, electrically operated.
    • Size of Product: Φ218*204 mm.
    • Releasing Time: 15 to 19 seconds.
    • Device Weight: 8400 grams.
    • Sealing material: aluminum foil.
    • Number of Nozzles: 20 nos.
    • Environment Temperature: -40℃ to +108℃.
    • Relative Humidity: up to 95% at a temperature of 20℃.
    • The Cylinder’s Surface Temperature: is less than 100℃.
    • Cylinder’s Nozzle Temperature: less than 200℃.
    • The Life span of an Aerosol Agent: is 10 years.

    The aerosol-fixed fire extinguishing systems are clean and not corrosive to electronic equipment in telecom rooms, which is why aerosols can be used to protect all types of power distribution facilities.

    There are 2 Safeguards in the aerosol solution for the telecommunication room, as follows:

    • Safeguard 1: Installation of large aerosols for overall protection of telecommunication rooms, e.g. model AW-QH-1500E.
    • Safeguard 1: Installation of small aerosols to protect individual switchboards, e.g. model AW-QH-30TH.

    In the telecommunication room, there are also network switch cabinets over there, these different sizes of cabinets also need to be protected by smaller-sized aerosol fire extinguishers or pipeless fire detection tube systems.

    250 gram electrical activation fire extinguishing devices for substation

    Every product is unique, and so are aerosols. Here are the strengths of aerosol fire suppression systems:

    • Highly effective based on its design density of 100 grams per cubic meter.
    • Environmentally friendly to the human body and animals.
    • Compact and weight save, it could be installed on the wall or the ceiling.
    • Its service life is long, almost 10 years.
    • The shell material is 304 stainless steel, making it durable.
    • It is waterproof and dustproof, Ingress Protection grade is IP67.
    • It is a DIY installation product, which is easy to install.
    • International certificates and approvals to support.

    It is widely applied in the below fields but is not limited to:

    • Battery energy storage and battery room.
    • Server room.
    • IT computer room.
    • Transformer room.
    • data processing room.
    • Chemical storage room.
    • Elevator machine room.
    • Vehicle engine bays.
    • Gas turbine enclosures.
    • Lifting and handling equipment.
    • Marine engine room.
    • Pump houses.
    • Elevator rooms.
    • Gen-set or generator set.
    • Big capacity power inverter.
    • EV charging system.
    • Control panels.

     

    This product is operated automatically, and normally works with Corresponding fire alarm systems together to fulfill its function of automatic operation:

    • Fire alarm panel.
    • Manual call point.
    • Heat detector.
    • Smoke detector.
    • Flame detector.
    • Start button.
    • Flash lamp visual alarm.
    • Gas release indicator.
    • Aspirating smoke detection system.
    • Liner heat detection.
    • Activation device.
    • Power supply unit c/w backup battery.
    • Fireproof cable.

    Enquiry Form ( we will get back you as soon as possible )