Sind alle für die Sicherheit,für eine sichere Welt!

Feste Feuerlöschsysteme, elektrisches Aerosol

» Produkte » Minisol Aerosol Feuerlöscher » Fixed Fire Extinguishing Systems Electric Aerosol
  • Feste Feuerlöschsysteme, elektrisches Aerosol

    KATEGORIE UND TAGS:
    Minisol Aerosol Feuerlöscher, Produkte

    Our aerosol-fixed fire extinguishing system produces a super-fine aerosol compound, which is a clean agent without damage to electrical equipment.

    Aerosol systems can be installed in telecommunication rooms where high-value equipment is over there.

    Anfrage
    • Technische Daten
    • Eigenschaften
    • Anwendung
    • Mehr Informationen

    The electric style of aerosol fixed fire extinguishing systems are ideal products for protecting the telecommunication room, Before we formally introduce fire extinguishers, let’s understand what is a Telekommunikationsraum.

    In a telecommunication room, there are many electrical equipment over there: Netzteile, signal transceivers, SDH-Übertragungsgeräte, Basisstationsausrüstung, Stromverteilerkasten, Umgebungsmonitor, Optischer Verteilerrahmen, Digitaler Verteiler, Kabellose Geräte, Zugriffsgeräte, and Switching equipment.

    The telecommunication room also named carrier hotel, is where many electric and electrical equipment works, Es ist also ein sehr wichtiger Ort, According to the code for fire protection design, there should be set with automatic fire suppression systems, ortsfeste Aerosol-Feuerlöschanlagen mit 1500 compounds are recommended.

    Basic Technical Parameters of Aerosol Fixed Fire Extinguishing Systems

    Im Folgenden sind die grundlegenden Parameter aufgeführt:

    • Name: Fixed Aerosol fire extinguisher.
    • Produktmodell: AW-QH-1500E
    • Kapazität: 1500 Aerosolbedeckung bis zu 15 Kubikmeter.
    • Aktivierungsmodus: elektrisch, elektronisch, electrically operated.
    • Größe des Produkts: 218*204 mm.
    • Freigabezeit: 15 nach 19 Sekunden.
    • Gerätegewicht: 8400 Gramm.
    • Dichtungsmaterial: aluminum foil.
    • Number of Nozzles: 20 nos.
    • Umgebungstemperatur: -40℃ bis + 108 ℃.
    • Relative Luftfeuchtigkeit: bis zu 95% at a temperature of 20℃.
    • The Cylinder’s Surface Temperature: is less than 100℃.
    • Cylinder’s Nozzle Temperature: weniger als 200℃.
    • The Life span of an Aerosol Agent: ist 10 Jahre.

    The aerosol-fixed fire extinguishing systems are clean and not corrosive to electronic equipment in telecom rooms, which is why aerosols can be used to protect all types of power distribution facilities.

    Es gibt 2 Safeguards in the aerosol solution for the telecommunication room, as follows:

    • Safeguard 1: Installation of large aerosols for overall protection of telecommunication rooms, e.g. model AW-QH-1500E.
    • Safeguard 1: Installation of small aerosols to protect individual switchboards, e.g. model AW-QH-30TH.

    Im Telekommunikationsraum, there are also network switch cabinets over there, these different sizes of cabinets also need to be protected by smaller-sized aerosol fire extinguishers oder pipeless fire detection tube systems.

    250 Gramm elektrische Aktivierungs-Feuerlöschgeräte für Umspannwerke

    Every product is unique, and so are aerosols. Here are the strengths of aerosol fire suppression systems:

    • Hocheffektiv aufgrund seiner Konstruktionsdichte von 100 Gramm pro Kubikmeter.
    • Environmentally friendly to the human body and animals.
    • Kompakt und gewichtssparend, it could be installed on the wall or the ceiling.
    • Seine Lebensdauer ist lang, schon fast 10 Jahre.
    • The shell material is 304 rostfreier Stahl, making it durable.
    • Es ist wasser- und staubdicht, Eindringschutzgrad ist IP67.
    • It is a DIY installation product, which is easy to install.
    • Internationale Zertifikate und Zulassungen zur Unterstützung.

    It is widely applied in the below fields but is not limited to:

    • Batteriespeicher und Batterieraum.
    • Serverraum.
    • IT-Computerraum.
    • Transformatorraum.
    • Datenverarbeitungsraum.
    • Lagerraum für Chemikalien.
    • Aufzugsmaschinenraum.
    • Vehicle engine bays.
    • Gasturbinengehäuse.
    • Hebe- und Handhabungsgeräte.
    • Schiffsmaschinenraum.
    • Pumpenhäuser.
    • Aufzugsräume.
    • Gen-Set oder Generator-Set.
    • Wechselrichter mit großer Kapazität.
    • EV-Ladesystem.
    • Die Steuertafeln.

     

    Dieses Produkt wird automatisch betrieben, and normally works with Dazugehörigen Brandmeldeanlagen zusammen, um seine Funktion des automatischen Betriebs zu erfüllen:

    • Brandmelderzentrale.
    • Handfeuermelder.
    • Wärmemelder.
    • Rauchmelder.
    • Flammenmelder.
    • Start Knopf.
    • Flash lamp visual alarm.
    • Gasfreisetzungsanzeige.
    • Ansaugrauchmeldesystem.
    • Liner-Wärmeerkennung.
    • Aktivierungsgerät.
    • Power supply unit c/w backup battery.
    • Fireproof cable.

    Anfrageformular ( wir werden wieder so schnell wie möglich erhalten )