Sind alle für die Sicherheit,für eine sichere Welt!

Zwei weitere Möglichkeiten zur Installation von Minisol-Aerosolgeneratoren

» Technology Support » Zwei weitere Möglichkeiten zur Installation von Minisol-Aerosolgeneratoren

Zwei weitere Möglichkeiten zur Installation von Minisol-Aerosolgeneratoren

Juni 6, 2019

Description of our Extinguishing nozzle on the Minisol aerosol generators

The extinguishing nozzles of Minisol are set in two locations, Eine Stelle befindet sich am Boden des Aerosolgenerators, and another location is on the top of the aerosol device, Normalerweise mögen Leute die Düse am Boden, but some special projects require a magnet with 3m glue to install, Dann sollte die Löschdüse nur oben auf dem Aerosolgenerator angebracht werden.

Normally if the extinguishing nozzles are set on the bottom of the aerosol, then use an installation bracket to install it if the extinguishing nozzles are set on the top of the aerosol, Verwenden Sie dann zur Installation Magnete zusammen mit 3M Kleber, but you also can choose to have installation bracket.

The first way to install Minisol aerosol generators – Durch Verwendung von Montagewinkel und Schrauben

This is the best way to install Unser Aerosolgerät in many projects in the wind power room, Generator-Raum, mobiler Motor, and machines, normally people purchase our product we use an installation bracket, the advantage of using an installation bracket is the aerosol generators can be firmly anywhere, um zu verhindern, dass es nach der Installation herunterfällt.

Also, wenn die Löschdüse unten ist, Verwenden Sie besser diese Montagehalterung(mit Schrauben) installieren.

The installation bracket is made up of stainless steel iron and it is strong and anti-corrosion, by using it you do not worry about it getting corrosion.

Installation brackets includeU-shaped” und “L-shapedbrackets, please see the photos showing:

  • Minisol-Aerosolgenerator -1
  • Luftfahrtstecker -2
  • Kabeldraht -3
  • Runder Reifen -4
  • Halterungsanschlüsse 1 -5
  • Halterungsanschlüsse 2 -6
  • L-förmige Montagehalterung -7
  • Flaches Pad -8
  • Federkissen -9
  • Sechskantschrauben -10
  • U-shape installation bracket -11

Normally for a small size of minisol aerosol, use an “L” Form einer Montagehalterung, and for a medium or large size of minisol aerosol, then use a “U.” Form einer Montagehalterung.

The second way to install Minisol aerosol generators is by using magnets with 3M glue

This is the special way to install our aerosol generator in some projects that are not suitable to use the installation bracket to install, aber geeignet, um Magnete mit zu verwenden 3M Kleber installieren.

Bei Verwendung von Magneten mit 3M Kleber zur Installation müssen die Löschdüsen des Aerosolgeräts auf der Oberseite eingestellt werden, and the protection object must be with the material of iron or stainless steel so that the magnetic and 3M glue can be adhered to it.

The advantages of using magnets with 3M glue is also easy to install, but not as firmly installed as by using an installation bracket, so if not for special projects, then use an installation bracket, but for some special projects better to use magnets and 3M glue to install, dann werden wir einige spezielle Vorschläge machen.

Nowadays aerosol fire suppression device is recognized worldwide and many engineering and installation companies and firefighting enterprises think aerosol suppression is a good fire protection solution for them, so they like to design aerosol systems for their ongoing projects.

Different Installation Modes

The following industries or fields are places that require a Minisol fire suppression device with different installation modes:

  • Windkraftindustrie, the wind turbine nacelle, Steuerplatine, und Schaltschränke.
  • Transportindustrie, Bus, Trainer, LKW, Autos, and some other heavy-duty vehicles, beispielsweise, our car needs to install a fire suppression system, we suggest installing our aerosol suppressant generators inside the car engine, with the capacity of covering 1.5 nach 2.5 Kubikmeter.
  • Kommunikationsindustrie, in the communication industry there are many electrical equipment cabinets, control boards, and electronic boxes that need to be protected by a small fire suppression device, wie Aerosol.
  • Energiewirtschaft, The power industry includes wind power, power generators, Machtverteilung, and many electrical cabinets are over there.
  • In public places and municipal facilities, such as power distribution cabinets, Tunnel, Brücken, gas supplies, water supplies, and power supplies, the electronic equipment also may require a small aerosol fire suppression system to protect it.
  • Offshore-Plattform Industrie, a transformer room in an offshore platform always needs such small fire suppression system to protect it, wie dieses Aerosol.
  • Batterieindustrie, Nowadays new energy is developing so fast, and people have great requirements for battery products, so now some companies have been researching to install a small fire suppression generator inside a battery space, und unsere Aerosolgeräte können.
  • Bauindustrie, In einem Kontrollraum für schwache und starke Ströme in Gebäuden kann eine Aerosol-Brandbekämpfungsvorrichtung zum Schutz eingesetzt werden.
  • Andere, we can not be able to list all but we can imagine this small aerosol fire extinguishing device is be able to applied everywhere.

About Bracket Installation

So industries and fields better use Brackets to install, and some better use magnets and 3M brand glue.

Um festzustellen, welche Installationsmethoden verwendet werden, sollten Sie sich zuerst bei uns erkundigen, and tell me some basic information about the following:

  • Projektname, Dies ist, um zu wissen, wo das Gerät installiert werden soll.
  • Welche Funktion möchten Sie?, automatisch, Handbuch, or both of them?
  • Installationsumgebung und Umgebungstemperatur erforderlich.

After we get your inquiry we will ask you for the basic information and then will require you to give us more information, die Informationen einschließlich einer der folgenden:

  • Project drawings in DWG format or PDF or in JPG format.
  • Projektmaterial-Anforderungslisten (Angebotsanfrage).
  • Abmessungen und Spezifikationen.

After that we will send an inquiry to our design department in the company and the technician will work out a fire solution for your project.

We are an efficiency-oriented manufacturing company and we design, produzieren, engineer, and install a variety of our fire suppression systems and their devices: Sprühdose, FM200, ig541, CO2, Trockenpulver, TAG, etc.

We are an efficiency-oriented manufacturing company and we design, produzieren, engineer, and install a variety of fire suppression systems and their devices: Sprühdose, FM200, IG541, Kohlendioxid, Trockenpulver, TAG, und so weiter.

Verweise

  • GA499.1-2010, Aerosol-Feuerlöschsysteme – Condensed Aerosol Feuerlöschvorrichtung.
  • NFPA 2010, Standard für Feuerlöschsysteme mit festem Aerosol.
  • ISO 15779, Condensed Aerosol Feuerlöschanlagen.
  • ANSI / UL 2775, Standard für feste kondensierte Aerosol-Löschsystemeinheiten.
  • CEN / TR 15276-1/2, Feste Brandbekämpfungssysteme - Kondensierte Aerosol-Löschsysteme.
  • KIWA-k23003 Feuerlöschsysteme auf Basis von Trockenaerosol.
automatische Feuerlöschsysteme für Umspannwerksverteilung Raumschalttransformator

Innovative Technologie automatische Feuerlöschsysteme für Schalttransformator für Umspannwerke

Für Details bitte lesen und herunterladen INSTALLATIONSANLEITUNG von 304 edelstahl fixiertes aerosol.

    Weitere Produkte zur Brandbekämpfung anzeigen

    Vielleicht gefällt Ihnen auch