Doen alles vir veiligheid,vir 'n veilige wêreld!

Fire Protection Analysis: The Renewable Energy Sector

» ons Blog » Fire Protection Analysis: The Renewable Energy Sector

Fire Protection Analysis: The Renewable Energy Sector

Februarie 18, 2023

Many applications in the field of renewable energies require fire protection systems (Brandblussers).

In this article, we describe in detail the applications, optrede, and suitability of fire protection systems for photovoltaic, energieberging, and wind power.

Wind Power Fire Protection

Nou, nuwe energie ontwikkel vinnig, en brandbeskerming op die gebied van nuwe energie sal die fokus wees, alle soorte ondernemings regoor die wêreld het begin fokus op die ontwikkeling van hernubare energieprodukte, Die produkte sluit litiumbatterye in, Litium-ioon-batterypakke, sonpaneel, omskakelaar, energie stoor houer, UPS krag, kragtoevoer, draagbare kragstasie, windkragopwekker, elektriese voertuig, laaipak, waterstof energie, kernenergie ens.

vuur onderdrukking stelsel vir wind turbine vure

Kortom, die belangrikste nywerhede van hernubare energie kan opgesom word as “wind krag, sonenergie, energy storage and automobiles”, namely “windkrag”, “fotovoltaïese”, “energieberging” en “motors”. Windkrag, photovoltaic and energy storage belong to the power generation field, while automobiles belong to the consumption field.

The main equipment in the wind power generation industry is the wind turbine. Wind turbines are not only expensive to build, but also have difficulties in terms of fire prevention. People usually install ABC dry chemical powder fire extinguishers and aerosol fire extinguishers in wind power generation systems. The dry powder system is installed in the wind turbine nacelle for total flooding protection. While the aerosol system can protect the electrical cabinets inside the tower and on the base.

Photovoltaic Fire Protection

Wat fotovoltaïese betref, it mainly consists of solar batteries, beheerders, panele, junction boxes, combiner boxes, omsetters, and solar panels. inverters are the main components that need fire protection, want hulle word dikwels warm, en hulle is elektriese komponente.

Volgens ons waarneming en ontdekking, an aerosol fire extinguishing system is the best choice for photovoltaic solar energy.

In Sjina, in fact that the most common type of photovoltaic fire extinguishing system is aerosol.

Energy Storage Fire Protection

Energieberging het eers in onlangse jare gewild geword, daar is baie stroomop en stroomaf produkte betrokke, byvoorbeeld, mynboutoerusting vir litium, nikkel, cobalt, and other mineral resources, Battery en battery materiaal, nuwe energievoertuie, stapels laai, energie stoor houer stelsel, UPS krag, mikro module kabinet.

The energy storage system has high requirements for fire extinguishing agents, so it is difficult to choose an ideal fire extinguisher. Volgens die navorsing van buitelandse navorsingsinstellings, die aërosol, the heptafluoropropane, en die NOVEC 1230 stelsels is beter keuses.

Fire protection for small Spaces, using aerosols to save installation space. For fire extinguishing in large Spaces, heptafluoropropane and FK5112 are more economical.

Fire Protection for Electric Vehicles and Electric Vehicle Related Products

Wat voertuie betref, It is a consumer products, daar is baie nuwe energieverbruikersprodukte, soos stapels laai, nuwe energievoertuie, portable power stations, on-grid and off-grid solar systems, en so aan, al hierdie produkte is ook elektriese toerusting, hulle het gewoonlik brandbeskerming nodig om te verhoed dat hulle termiese weghol raak.

Selection of Different Fire Protection Systems

Tans, there are several main types of fire extinguishing systems (extinguishing agents) for the new energy industry:

  • Aërosol.
  • Heptafluoropropane.
  • NOVEC 1230.

The advantages of aerosols are non-pressure storage, geen pypnetwerk installasie nodig nie, en het 'n hoë veiligheidsfaktor. Heptafluoropropane has the advantage of high fire extinguishing efficiency. The advantage of NOVEC 1230 is dat dit meer omgewingsvriendelik is as FM200, en die brandblusdoeltreffendheid is ook baie goed.

The usual choices are:

  • For small spaces, such as an electrical cabinet, litium battery, meter boks, laai kragstasie, omskakelaar, ens, use an aerosol system.
  • For bigger spaces, such as energy storage rooms, mynbou toerusting, kragopwekkingskamers, ens, use the FM200 system or NOVEC 1230 stelsel.
  • Some places were not able to use FM200, NOVEC 1230, en aërosol, so we chose to use the ABC dry chemical powder system instead.

Natuurlik, we need to analyze the specific situation based on the actual installation environment.

Brandbeskerming is nie 'n maklike taak nie, wat begroting behels, ontwerp, konstruksie, and installation.

daarom, ons moet toepaslike brandblusprodukte kies volgens die werklike situasie.

Green Renewable Energy and Fire Protection

Groen hernubare energie is die neiging van toekomstige ontwikkeling, world-famous companies are vigorously deploying new energy businesses, and the business scope includes power generation equipment, kragtransformasie- en verspreidingstoerusting, vuur beskerming, energieberging, etc Who can enter the new energy bureau first, and who can benefit earlier?

Energy storage fire protection is an industry that combines fire protection and new energy, and it is currently a trend all around the world.

We need to protect the lithium battery in the energy storage cabinet(houer) well and select suitable fire extinguishing agents for it.

For the selected energy storage fire extinguishing agent, we require that it not only be able to extinguish fire, but also not damage the lithium battery and pollute the environment.

Tans, die oorgrote meerderheid brandblusstelsels op die mark is nie geskik vir die beskerming van nuwe energieprodukte nie, veral litiumbatterye op die gebied van energieberging. Deur navorsing, we find out that most of our fire suppression systems are not successful in extinguishing fires in lithium batteries, battery boxes, and energy storage cabinets.

Hybrid Inverter Fire Extinguishing Units

Selection and Types of Energy Storage Fire Extinguishing Systems

After continuous exploration, new energy companies and research institutes have found that 3 types of fire extinguishing systems can be used as fire protection solutions for energy storage:

  • Aerosol brandblusstelsels.
  • HFC-227ea gas or NOVEC 1230 stelsels.
  • ABC dry chemical systems.

Aerosol systems are typically installed within lithium battery packs to protect each pack individually. Daarteenoor, HFC-227ea/NOVEC 1230 gas and ABC dry-chemistry systems are typically installed in the energy storage containers(kas) along with a fire alarm system and pipework.

In werklikheid, in the new energy (hernubare industrie), the best fire protection solutions are aerosol systems, piped HFC-227ea gas (of NUUT 1230 gas), and fire alarm systems.

Their main roles are as follows:

  • Fire Alarm Systemdetects fire and automatically activates the fire suppression system.
  • HFC-227ea of ​​NOVEC 1230 gas systemsextinguish fires in larger container spaces.
  • Aerosol extinguisher Unitsprotect lithium batteries, batterypakke, Battery cabinets, and inverters.

HFC-277ea system or NOVEC 1230 system is generally larger with bottles and pipe network, mainly used in energy storage containers. so we usually ask customers to provide layout drawings or site photos during installation.

Aërosol brandblussers, especially lithium-ion battery fire extinguishers, is klein in grootte, are mainly used in battery packs and cabinets.

In the future, fire protection in the new energy sector will be diverse, featuring multi-oxidation platforms, a wide range of fire protection facilities, and a variety of fire extinguishing agents. Let’s wait and see.

Minisol brandblusstelsel Device vir vervat Energie Storage System

 

Miskien het jy wil ook