    Floor-standing aerosol fire suppression device system AW-QRR10LW is a large-sized fire extinguishing system covering 71 cubic meters of closed space.

    enquiry
    • Specifications
    • Features
    • Application
    • More Information

    The floor-type aerosol fire-fighting device generally needs to cover a relatively large defense area, so a design concentration of 140 grams per cubic meter is required.

    A 10-kilogram aerosol extinguishing device can extinguish fires in 71 cubic meters of space, and this extinguishing efficiency is quite high.

    In some places where a water mist system, foam fire extinguishing system, and gas fire extinguishing system cannot be installed, this floor aerosol fire fighting device will be a better choice.

    The product not only has a startup function but also has a feedback function. If necessary, it can also work together with the alarm system.

    aerosol system fire suppression device for no break room

     

    The following are the parameters of this 10kg aerosol fire extinguisher product:

    • Model Number.: AW-QRR10LW/S.
    • Operating Temperature: -20 to +55℃.
    • Relative Humidity: ≤95%.
    • Designed Density: 140 grams/m³.
    • Working Voltage: DC 3~24Volts, or AC 3~220Volts.
    • Working Current: 1A/5ms.
    • Safety Current: ≤150mA/5min.
    • Operating Current: ≧250mA/5ms.
    • Size: 610*310*690 millimeters.
    • Cover Area: 71 m³.
    • Mass of Aerosol Chemical: 10000 grams.
    • Trigger Mode: Electrical or Electronics.
    • Color: Milk White, Red, or Black.
    • Cylinder: Steel with polishing.
    • Outlet Temperature: 175±5 degrees Celsius.
    • Gross Load: 54 kilograms.
    • Net Load: 10 kilograms.
    • Life Span: 7 to 10 years.
    • Type of Fire: A, B, C, E.
    • Delivery Time: 8 to 10 days.

    E-mail us to get more files about this ground-type aerosol extinguisher.

    Recommendation for Ceiling Mount Aerosol Fire Extinguishing System with various specifications.

    • Green product with ODP=0,ALT=0,GWP=0, environmentally friendly.
    • Non-toxic, Non-corrosive, Non-Conductive, No residue after suppression.
    • easy to install, just place it on the corner of the floor, and with the correct wire connection.
    • No pressurized, the cylinder and aerosol powder don't need any pressure to work.
    • high quality with new and innovative technology in the fire extinguisher industry.
    • stand-alone systems and other power systems to work.
    • Newest Aerosol Fire Technology.
    • Low in Maintenance every year, no need for yearly inspection.
    • high efficiency in fire extinguishing and suppression for fire-fighting.

    The automatic aerosol fire-fighting device system AW-QRR10LW is a total flooding the fire hazard, it is perfect for extinguishing fire.

    It can be used in computer data center rooms, processing rooms, museums, libraries, communication rooms, power generator rooms, transformer substations, distribution substation rooms, switch rooms and switch gears, electrical control rooms, oil storage rooms, flammable liquid storage, and factory workshops.

    It can apply in the following industries, but is not limited to them:

    • Wind Power industry.
    • Communication Industry.
    • Transportation Industry.
    • Petroleum and Petrochemical Industry.
    • Construction Industry.
    • Metallurgy Industry.
    • Mining Industry.

    For more application ranges, please refer to our catalogue and installation manual.

    When installing, maintaining, and commissioning this product, please pay attention to the following matters:

    • This product is heavy, so install it by moving it to the desired mounting location before doing any other wiring.
    • The product extinguishing agent is relatively large, up to 10kg. So, please make sure to cut off the circuit first when wiring.
    • When installing, ensure that no obstacles are blocking the nozzle at 1 metre.
    • Keep the room dry. Keep fire extinguishing agents in a dry condition to extend the life of the device.

    The biggest problem encountered during installation, commissioning, and maintenance may be electrical and wiring problems, and professional assistance should be sought for installation.

    We can provide technical guidance remotely.