The Electromagnetic mode suspended FM200 firefighting system is made up of an HFC-227ea extinguishing agent and its storage cylinder, behållarventil, munstycke, electromagnetic drive device, signal feedback device, tryckmätare, suspended bracket, etc.
As you can see, it comes with mounting hooks for hanging from the ceiling. The advantage of being mounted on the ceiling is that it saves space and doesn’t take up floor space.
I händelse av brand, it can provide a rapid spray of extinguishing agent from a ceiling-mounted position for full flooding of the containment area.
Suspended Heptafluoropropane has a relatively small capacity of 10 till 40 litres, so they are mainly used in smaller fire zones, inklusive:
Dieselgeneratorrum.
Switchboard house.
Bank Vault.
Oljeförvaringsrum.
Small computer room.
Small engine room.
UPS room.
Transformatorrum, etc.
You need to just install one of these extinguishing units in each small space according to the gas extinguishing design formula.
As you can also see, it has temperature-controlled glass globes, which are automatically activated with temperature control. But if you require the electric start function, it can do that too.
Basic Technical Data Sheet of the 1.6 MPA Electromagnetic FM200 FireFighting System
The following is the basicTECHNICAL DATA SHEETof the suspended FM200 firefighting system:
Model number.: XQQC-10/1.6, XQQC-20/1.6, XQQC-30/1.6, XQQC-40/1.6.
Maximum operating pressure: 2.5 MPa (20 grader Celsius).
Extinguishing agent filling density(concentration): no more than 1.15kg/L.
Activation power: 24 VDC.
Suppression mode: Total översvämning.
Time of fire suppression: No more than 10 Sekunder.
Pilot gas: Nitrogen.
Working environment temperature: -40 till +70 grader Celsius.
Anmärkning: About the model number, we take XQQC10/1.6 for example. “XQ” betyder “suspended fire suppression device”. The second “Q” betyder “HFC-227ea”. “C” means the activation mode is electromagnetic “10” means the agent storage cylinder is 10 Liters. “1.6” means storage pressure is 1.6 MPa.
In the following table, we list the capacity details about this 1.6 MPA suspended FM200:
The biggest difference compared tosuspended dry powder fire extinguishing systemsis that suspended dry powder systems can locally extinguish fires, while suspended perfluorohexane must be installed in enclosed spaces.
Here is a short video to show you the fire extinguishing effect of a suspended Heptafluoropropane fire extinguishing device:
The suspended electromagnetic mode of the FM200 fire suppression device is smaller in size than the cabinet model and the piping mode has the following features and advantages:
Small in size and hangs on the top ceiling or the wall, so it isspace-saving.
Do not require to installation extinguishing agent transmission pipeline.
Do not require a specialized hfc-227ea agent cylinder storage room.
Fire Extinguishing speed is super fast, within only 10 sekunder.
Easy to do maintenance and easy to install.
Not only for small spaces but also for big spaces.
Clean products and eco-friendly to the environment.
Thermal cord activation and electrical activation together.
OEM service and labeling service are available.
This suspended HFC-227ea fire suppression device can be able to apply in:
Solid surface fire.
Liquid fire.
The gas fire can be cut off from the gas source before suppression.
Electrical fire.
Typical Application Sites are: Elektronisk datorrum, databehandlingsrum, telecommunications facilities, process control center, Expensive medical facilities, Precious industrial equipment, Museum, Art Gallery, Bibliotek, Reference Room, Valuables room, Emergency power facility, Flammable liquid storage area, Clean factory, etc these key places' fire protection solution.
Also can apply in production and processing places: Cargo Painting room and production line, electrical aging room, rolling mill, printing machine, melting groove, torkutrustning, coal powder warehouse.
And vehicle engine room compartments, specially can apply in small spaces.
Dessutom, it can also be used in the following places:
Low-pressure test room.
Seawater immersion room.
Mechanical impact room.
Extrusion and nail room.
Overcharge room.
Hot box room.
Short circuit room.
Tool room.
Kontrollrum.
Scrap soaking room.
Air conditioner and dehumidifier room.
HFC-227ea agent
The HFC-227ea agent is the main extinguishing agent, it is a chemical and physical fire suppression media, den är färglös, tasteless, clean, och icke-ledande, it is very safe for the human body and environmentally friendly.
Fire Alarm System and Fire Detection Elements
This product normally works withgasbrandlarmssystem, inklusive: gas fire control panel, brandvarnare, värmedetektor, manuell utlösningspunkt, indicator, sounder and strobe, alarm bells.
Förfrågningsformulär ( vi återkommer så snart som möjligt )